Eclipse 32
Description
Zone inputs: 8 physical inputs on control panel for connecting of detectors.
Max Zones: 8 / 16 zones with freely programmable parameters (with possibility for expanding up to 32).
Zone Wiring: 9 types, single or doubling zone connection.
Areas: 8 independent areas.
Access control: via proximity card readers. 8 Time slots (tables) to manage the user access to the protected sites. Every time slot can be programmed individually according the system requirements. Auto Arming mode for arming the security areas in preprogrammed time.
Outputs: 4 weak current and 1 power current programmable outputs type ОС (open collector) on the control panel. Expanding up to 32 outputs using PGM expander module. Same options for programming of all outputs. PGM4 can be programmed to operate as fire zone using 2-wire connection of a standard 24V fire base.
Codes: 4/ 6 digit; 64 User codes, 1 Maintenance code, 1 Engineer code.
Memory LOG: 1024 events with time and date – can be viewed by a keyboard or via ProsTE software.
Report to a Monitoring Station:
Built-in digital communicator for central station monitoring via telephone line. “Contact ID” and “SIA” standard protocols are supported.
TTE GPRS Standard and TTE GPRS Simple communication module.
Peripheral Devices: Up to 30 devices connected to the system bus.
LCD and LED keyboards.
Proximity card reader.
PGM8 – PGM outputs expander.
ZONE8 – Zone expander.
Eclipse WL – Wireless expander.
Programming: 3 types of programming menus
4-digit addresses
3-digit operations
Text menus – tree structure
Mains transformer | 21 VAC /50VA |
Accumulator battery | 12 V / 7 Ah |
Current consumption | 100 mA |
Power output | 3.8 V DC / 1A, resettable fuse |
Operating temperature range | from 0°C to 50°C |
Enclosure box | ABS plastic, white |
Dimensions | 335 x 290 x 105 mm |